Lumasense-technologies IGA 320/23 Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
IMPAC pyrometer IGA 320/23
14
7 Software InfraWin
Additionally to parameter adjustments the software InfraWin features the possibility of recording measure-
ment values inclusive displaying temperature measuring curves and subsequent analysis and storage.
This section gives an overview about the functions of the software. Additionally there is a software descrip-
tion in the program’s help menu.
The following descriptions refer to the program version 4.13. The latest version is available for free as
download from the homepage www.lumasenseinc.com.
7.1 Connecting the pyrometer to a PC
The p
rogram InfraWin can operate up to two devices. Two devices using RS485 may be operated simulta-
neously by the same interface, if two different addresses have been properly entered (see 6.14 Address).
7.2 Installation
For in
stallation select the setup program “setup.exe“ from the InfraWin-CD or from the downloaded and un-
packed zip file from the internet and follow the installation instructions.
7.3 Program start
After install
ation and the first program start a language must be chosen (German, English, French, Italian
and Spanish. The language also can be changed in the program). On the start page the screen shows the
following icons:
7.4 The start menu
Opens a saved file
Storage of measured values for further processing
Online measurement with color bar display
Online measurement with graphic display
Setting of the parameters of the instrument
Setting of interface, baud rate and pyrometer addresses (RS485)
Time interval between two measurements
Number of connected instruments (max. 2)
Listing of measured or stored values in tabular form
Processing of measured (stored) readings in graph form
Processing of measured (stored) readings in a text file
Calculation of spot sizes in various measuring distances
Only if available: controls the programmable controller PI 6000
7.5 Beginning
Before using the software, the serial interface connected to the pyrometer has to be selected under
the Computer icon. For two devices using the RS232 interface, two PC interfaces must be used.
7.6 Number of devices
With a click on “number of devices” InfraWin changes to the display of 1 or 2 devices. If 2 devices
are selected, always 2 windows are displayed for settings or evaluation.
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 47 48

Commentaires sur ces manuels

Pas de commentaire