Lumasense-technologies IGA 6/23 Advanced Manuel d'utilisateur Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
IGA 6/23 Advanced Manual Data format UPP
Ò
· 39
Description Command Parameters
Read Parameters Aapa Answer: 15 decimal digits
DD............. : Emissivity (see em)
..D............ : Response time (see ez)
...D........... : Clear peak memory (see lz)
....D.......... : Analog output (see as)
.....DD........ : Internal temperature (see gt)
.......DD...... : Device address (see ga)
.........D..... : Baud rate (see br )
..........01000
: Fixed value
Serial number AAsn Output: XXXXX (hex 5-digit)
Device type /
Software version
AAve Answer: VVMMJJ VV=27
MM=Month JJ = Year of software version
Communication
Module/ software
version in detail
AAvc tt.mm.jj XX.YY
tt = day; mm = month; jj = year;
XX.YY = Software version
Software version in
detail
AAvs tt.mm.jj XX.YY
tt = day; mm = month; jj = year;
XX.YY = Software version
Note: the letter “l” means the lower case letter of “L”.
Additional instruction for the RS485 interface:
Requirements to the master system during half-duplex operation:
1. After an inquiry, the bus should be switched into a transmission time of 3 bits (some
older interfaces are not fast enough for this).
2. The pyrometer's response will follow after 5 ms, at the latest.
3. If there is no response, there is a parity or syntax error and the inquiry has to be
repeated.
4. After receiving the response, the master has to wait at least 1.5 ms before a new
command can be entered.
Vue de la page 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 45 46

Commentaires sur ces manuels

Pas de commentaire